1.9 KiB
Corsair HXi and RMi series PSUs
Support for these devices is still experimental.
Initialization
It is necessary to initialize the device once it has been powered on.
# liquidctl initialize
The +12V rails normally function in multiple-rail mode, and initialize
will by default reset the PSU to that mode; single-rail mode can be selected by passing --single-12v-ocp
to initialize
.
Note: changing the +12V OCP mode is currently an experimental feature.
Monitoring
The PSU is able to report monitoring data about its own hardware and basic electrical variables for the input and output sides.
# liquidctl status
Device 0, Corsair RM650i (experimental)
Current uptime 3:43:54
Total uptime 9 days, 11:43:54
Temperature 1 50.0 °C
Temperature 2 40.8 °C
Fan control mode Hardware
Fan speed 0 rpm
Input voltage 230.00 V
Total power 110.00 W
+12V OCP mode Multi rail
+12V output voltage 12.12 V
+12V output current 7.75 A
+12V output power 92.00 W
+5V output voltage 4.97 V
+5V output current 2.88 A
+5V output power 14.00 W
+3.3V output voltage 3.33 V
+3.3V output current 1.56 A
+3.3V output power 5.00 W
Fan speed
The fan speed is normally controlled automatically by the PSU. It is possible to override this and set the fan to a fixed duty value using the fan
channel.
# liquidctl set fan speed 90
This changes the fan control mode to software control and sets the minimum allowed duty value to 30%. To revert back to hardware control, re-initialize
the device.