UART(E): Duty cycle warnings due to Rx while Rx Off
This warnings can flood the terminal, let's dutty cycle them. Signed-off-by: Alberto Escolar Piedras <alberto.escolar.piedras@nordicsemi.no>
This commit is contained in:
parent
aa1f38d909
commit
a08acc7d3a
|
@ -464,7 +464,14 @@ void nhw_UARTE_digest_Rx_byte(uint inst, uint8_t byte) {
|
|||
bs_time_t frame_start, now;
|
||||
|
||||
if (u_el->rx_status == Rx_Off) {
|
||||
bs_trace_warning_time_line("Byte received while UART%i is not enabled for Rx, ignoring it\n", inst);
|
||||
static int Received_error_count;
|
||||
Received_error_count++;
|
||||
if ((Received_error_count & 0xFF) <= 4) {
|
||||
bs_trace_warning_time_line("Byte received while UART%i is not enabled for Rx, ignoring it (warn count = %i)\n", inst, Received_error_count);
|
||||
if ((Received_error_count & 0xFF) == 4) {
|
||||
bs_trace_warning_time_line("Silencing this warning the next 252 times\n", inst);
|
||||
}
|
||||
}
|
||||
return;
|
||||
}
|
||||
|
||||
|
|